Photogrammetry Scanner

Implantology has now gotten easier and more predictable

 

Full Arch Implants Impression

Pic dental is the world's best digital impression technique for multiple implants. The system always obtains an accurate impression regardless of the number of implants or their distances and angulations.

Implants Capture

Screw the PiC transfers onto the patient's implants and bring the PiC camera closer to obtain the implants positions in less than a minute.

PiC transfers are precisely placed, prior to capturing the measurements, on top of the implants or multi-unit abutments immediately after surgery or post healing as a step in the restorative phase. PIC transfers have a unique and customized pattern consisting of pre-measured marker dots. PiC dental system use photogrammetry technology to identify the vectors of each implant on an arch creating the most precise measurements which are interrelated. This allows for implant impressions to be captured among all implants digitally with up to 10 micron accuracy cross arch.

PiC camera and Software uses unique logarithms capable of full arch measurements in less than 1 minute. Patient information including case notes, implant positions along with system, size, healing cap and tooth position are entered into the system before measurements are taken. Once the procedure begins a viewer window opens on the computer screen to assist the user in capturing the precision measurements. PiC dental system is built to detect and alert if a PiC transfer shifts or was incorrectly selected ensuring a confirmed scan at completion.

Soft Tissue Registration

The next step is the acquisition of the contours of the soft tissues and the adjacent teeth via conventional impression or an intraoral scanner.

The easiest procedure is to scan the soft tissues with the healing caps, so they are also introduced in the PiC file to correlate the soft tissue data with the positions of the implants via Best Fit registration. The use of an intraoral scanner allows you to enter a digital workflow by scanning all the patient data needed for all implant restoration treatments. Sometimes, as in the case of the fully edentulous lower jaw, it is difficult to obtain a good impression of the soft tissues with an intraoral scanner due to moving parts such as the floor of the mouth or the vestibular areas near the lips, so that you take an alginate (keeping static the movable parts) and scan later this alginate with your iOS. This procedure is faster and more comfortable for the patient while the tuberosities and the alveolar ridge are better registered.

When taking a conventional impression to acquire the soft tissues, impression transfers are not needed, only healing caps (or Scan Bodies) must be visible over the gingiva in order to be correlated with the PiC file. If done on day of surgery then additional soft tissue impression will be necessary just after the suturing to detect changes occurring from healed tissue prior to delivering the final prostheses. Regardless of detection process, conventional impression or intraOral scanner, soft tissue is then superimposed with the PiC file to provide the world's most accurate and finest restoration.

 

Precise Digital Model

The PiC file with the implants positions interrelated and the soft tissue registration are aligned in a dental CAD software.

The last step of the PiC dental system is the creation of a digital master model, can be done easily in the Model Creator modules of all dental CAD. The introduction of digital workflows where your patient is scanned and displayed virtually on a screen changes the need to have a perfect master model. The prostheses are manufactured by milling machines while the models are manufactured in 3D printers, so there may be an accuracy discrepancy between the model and the prosthesis.

The virtual model is now more accurate than the physical model due to the addition of manufacturing errors through 3D printing or milling. Although milling machines used in laboratories and milling centers are more accurate than 3D printers, they always add a small manufacturing error, and although today the accuracy of 3D printers is improving, some error will always be added to the design of the prosthesis with respect to the scanned starting data.

The PiC Master model is manufactured combining the 5-axis milling machine and the 3D printer to have all the advantages of both manufacturing technologies.

Chairside

The complex task of taking an impression for a multi-implant structure is reduced to just a few minutes when including the insertion and removal of the PiC Transfers.

This results in:

  • Large savings in valuable chair time due to the easy placement of the PiC Transfers and the rapid measurements with the PiC Camera.

  • Predictable outcome as the result is independent of the skill Level of the user.

  • Elimination of costs for materials for taking the impression for multi-implants.

  • No re-tries as the first part will have a perfect fit.

Patient

The advantages for the patient include:

  • No stress due to the taking of the impressions. The insertion of the PiC transfers and the capture of the gingiva are rapid and comfortable compared to taking an implant impression.

  • The measurements can be performed with a lip extractor only. For the upper arch the mouth must be opened slightly and for the lower arch the mouth can be measured in the rest position. Thus there is no need to open the mouth to extreme positions as with intra-oral scanners.

  • The technology eliminates try-ins as the part will fit perfectly.

  • Improved comfort of the patient due to the quality of the fit of the final restoration.

  • Possibility of much shorter treatment times as early load protocols are much more feasible with the PiC Camera.

Laboratory

The work for the laboratory and/or dental technician is greatly reduced.

The advantages include:

  • No need for a stressful rapid production of models with gingiva mask and implant analogs.

  • No need to scan complex implant models.

PiC Transfers

The PiC transfers are custom manufactured for every implant platform. The four white dots identify each abutment by a photogrammetry code. The PiC transfers are engaged or non-engaged and are screwed into the patient's implants or transepithelial abutments. The PiC transfers can be manufactured for all implant brands, models and platforms